Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics

2011

This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…

PhysicsTotal harmonic distortionFrequency responsebusiness.industryAcousticsElectrical engineeringFundamental frequencycurrent transducerRogowski coilCurrent measurement current transducer frequency response harmonic distortion power system harmonics Rogowski coil.harmonic distortionHarmonic analysisAmplitudeHarmonicsHarmonicpower system harmonicElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coil
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct

Electron Emission of Pt: Experimental Study and Comparison With Models in the Multipactor Energy Range

2016

Experimental data of secondary emission yield (SEY) and electron emission spectra of Pt under electron irradiation for normal incidence and primary energies lower than 1 keV are presented. Several relevant magnitudes, as total SEY, elastic backscattering probability, secondary emission spectrum, and backscattering coefficient, are given for different primary energies. These magnitudes are compared with theoretical or semiempirical formulas commonly used in the related literature.

Secondary electron emissionBackscatterAstrophysics::High Energy Astrophysical PhenomenaCleaningElectronSecondary emission yield (SEY01 natural sciencesElectrostatic measurements010305 fluids & plasmasBackscattering coefficientBackscatterEnergy measurementElectron emission0103 physical sciencesElectron beam effectsTEORIA DE LA SEÑAL Y COMUNICACIONESElectron beam processingEmission spectrumElectrical and Electronic EngineeringElastic backscattering probabilityElectron emission spectraMultipactor energy rangePlatinum010302 applied physicsRange (particle radiation)ChemistrySecondary emission yield (SEY)Secondary emission spectrum (SES)PtElectron irradiationCurrent measurementElectronic Optical and Magnetic MaterialsElectron backscatteringSecondary emission yieldSecondary emissionYield (chemistry)Backscattered electronsDistortion measurementAtomic physicsEnergy (signal processing)Multipactor
researchProduct

A Non-Invasive Thermal Drift Compensation Technique Applied to a Spin-Valve Magnetoresistive Current Sensor

2011

A compensation method for the sensitivity drift of a magnetoresistive (MR) Wheatstone bridge current sensor is proposed. The technique was carried out by placing a ruthenium temperature sensor and the MR sensor to be compensated inside a generalized impedance converter circuit (GIC). No internal modification of the sensor bridge arms is required so that the circuit is capable of compensating practical industrial sensors. The method is based on the temperature modulation of the current supplied to the bridge, which improves previous solutions based on constant current compensation. Experimental results are shown using a microfabricated spin-valve MR current sensor. The temperature compensati…

EngineeringWheatstone bridgeSpin valvemagnetoresistance sensorlcsh:Chemical technologyBiochemistryArticleRutheniumtemperature compensationAnalytical ChemistryCompensation (engineering)law.inventionMagneticslawelectrical current measurementElectric Impedancelcsh:TP1-1185Current sensorElectrical and Electronic Engineeringspin-valve sensorInstrumentationbusiness.industryTemperatureElectrical engineeringEquipment DesignAtomic and Molecular Physics and OpticsOptoelectronicsConstant currentCurrent (fluid)businessFiber optic current sensorSensitivity (electronics)Sensors
researchProduct

Fractional Modeling of the AC Large-Signal Frequency Response in Magnetoresistive Current Sensors

2013

Fractional calculus is considered when derivatives and integrals of non-integer order are applied over a specific function. In the electrical and electronic domain, the transfer function dependence of a fractional filter not only by the filter order n, but additionally, of the fractional order α is an example of a great number of systems where its input-output behavior could be more exactly modeled by a fractional behavior. Following this aim, the present work shows the experimental ac large-signal frequency response of a family of electrical current sensors based in different spintronic conduction mechanisms. Using an ac characterization set-up the sensor transimpedance function  is obtain…

Transimpedance amplifierFrequency responseEngineeringMagnetoresistanceGiant magnetoresistancemagnetoresistance sensorfractional systemslcsh:Chemical technologyTopologyBiochemistryArticleAnalytical ChemistryCondensed Matter::Materials Scienceelectrical current measurementlcsh:TP1-1185Electrical and Electronic Engineeringsystems identificationInstrumentationSpintronicsbusiness.industryElectrical engineeringelectrical current measurement; magnetoresistance sensor; fractional systems; systems identificationCondensed Matter::Mesoscopic Systems and Quantum Hall EffectAtomic and Molecular Physics and OpticsFractional calculusTunnel magnetoresistanceFilter designbusinessSensors
researchProduct

Current characterisation for ultra low power wireless body area networks

2010

The emerging area of body area networks (BAN) imposes challenging requirements on hardware and software to achieve the desired lifetimes for certain devices such as long term medical implants. In this paper, we propose a novel approach to the measurement and characterisation of the energy consumption of BAN devices. The approach uses a low cost energy auditing circuit and addresses the problem of accurately measuring low-level current consumption. This new technique will allow precise and analytical measurements of systems and components in terms of energy. This will help circuit designers minimise power consumption in BAN devices. Software engineers might use this approach to validate and …

business.industryComputer scienceBody area networks Body sensor networks Circuits Costs Current measurement Energy consumption Energy measurement Hardware Implants Power engineering and energy Body Area Networks Current characterization Embedded system design Energy efficiency Power Consumption Wireless Network softwareEnergy consumptionPower (physics)SoftwareEmbedded systemCode (cryptography)Electronic engineeringWirelessbusinessEnergy (signal processing)Electronic circuitEfficient energy use2010 8th Workshop on Intelligent Solutions in Embedded Systems
researchProduct

Uncertainty evaluation in the measurements for the electric power quality analysis

2013

The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, according to the 'ISO - Guide to Expression of the Uncertainty in Measurements' all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors propagate through the measurement chain, a Monte Carlo based approach is proposed. The method exploits an ad-hoc developed simulator of the measurement process, which takes into account the particular way of propagation of all the identified error sources. Eventually, with the aim of validat…

EngineeringElectric power qualitymeasurement standardpower system measurementMeasurement uncertaintyMonte Carlo methodpower supply qualitySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciPower measurementpower quality analysisUncertainty analysisObservational errorelectric power quality analysiSeries (mathematics)business.industryProcess (computing)UncertaintyData acquisitionmeasurement uncertainty evaluationerror source identificationCurrent measurementExpression (mathematics)Reliability engineeringmeasurement systemISO standardguide to expression of the uncertainty in measurementMeasurement uncertaintybusinessad hoc developed simulatorNoiseAlgorithmSettore ING-INF/07 - Misure Elettriche E Elettronichemeasurement error
researchProduct

A novel approach to current transformer characterization in the presence of harmonic distortion

2009

The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…

EngineeringFrequency responseElectric current measurementAcousticsElectric transformer testingErrorsElectric utilitiesOperation conditionsHarmonic distortionPower companiesHarmonic analysisElectric power transmission networksFrequency responsePower electronicsWaveformMetering modeCurrent transformer (CT)Electrical and Electronic EngineeringInstrumentationNon-sinusoidal currentsPiezoelectric transducersTotal harmonic distortionbusiness.industryElectric power distributioncurrent transformer frequency response harmonic distortion power system harmonics transducersCurrent transformerRatio errorsTransducerElectric instrument transformersHarmonicPower system harmonicsCurrent (fluid)businessPower transmissionSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveforms
researchProduct

Quasi-digital conversion for resistive devices: application in GMR-based IC current sensors

2013

Resistive devices, including sensors, are used in a huge range of applications within different scenarios. When a complete system is considered, a quasi-digital output is often recommendable. If the conversion is operated at device level, some problems such as noise disturbs, insertion losses and so on, can be reduced. In this work, we describe a resistance-tofrequency (R-f) converter with a suggested application in low current monitoring by means of GiantMagnetoResistance (GMR) sensors. Specific devices have been designed and microfabricated. The system has been tested by means of discrete components with a PCB. The complete microsystem monolithic integration in a standard CMOS technology …

EngineeringElectric current measurementAnalog IC; Current measurement; GMR sensor; Oscillator; Resistance-to-frequency converter; Hardware and Architecture; Electrical and Electronic EngineeringOscillators (electronic)Noise (electronics)Electron devices:Enginyeria electrònica::Instrumentació i mesura::Sensors i actuadors [Àrees temàtiques de la UPC]Polychlorinated biphenylsMicrosystemElectronic engineeringOscillatorDigital conversionElectrical and Electronic EngineeringGMR sensorResistive touchscreenbusiness.industrySensorsElectrical engineeringElectromagnetisme -- MesuramentsAnalog ICResistance-to-frequency converterCMOS integrated circuitsCurrent measurementCMOSHardware and ArchitectureElectromagnetic measurementsvisual_artElectronic componentvisual_art.visual_art_mediumCurrent (fluid)business